How To Size Your Motor Back to Online Store |
||||||||||
| Spring Return Damper Actuators Width (mm)and Height (mm) |
||||||||||
| 250 | 0.31NM TF |
0.63NM TF |
0.94NM TF |
1.25NM TF |
1.56NM TF |
1.88NM TF |
2.19NM LF |
2.50NM LF |
2.81NM LF |
3.12NM LF |
| 500 | 0.63NM TF |
1.25NM TF |
1.89NM TF |
2.50NM LF |
3.12NM LF |
3.75NM LF |
4.38NM NF |
5.00NM NF |
5.63NM NF |
6.25NM NF |
| 750 | 0.94NM TF |
1.88NM TF |
2.81NM LF |
3.75NM LF |
4.69NM NF |
5.63NM NF |
6.56NM NF |
7.50NM AFR |
8.44NM AFR |
9.38NM AFR |
| 1000 | 1.25NM TF |
2.50NM LF |
3.75NM LF |
5.00NM LF |
6.25NM NF |
7.50NM AFR |
8.75NM AFR |
10.00NM AFR |
11.25NM AFR |
12.50NM AFR |
| 1250 | 1.56NM TF |
3.13NM LF |
4.69NM LF |
6.25NM NF |
7.81NM AFR |
9.38NM AFR |
10.94NM AFR |
12.50NM AFR |
14.06NM AFR |
. |
| 1500 | 1.88NM TF |
3.75NM LF |
5.63NM NF |
7.50NM AFR |
9.38NM AFR |
11.25NM AFR |
13.13NM AFR |
15.00NM AFR |
. | . |
| 1750 | 2.19NM LF |
4.38NM NF |
6.56NM NF |
8.75NM AFR |
10.94NM AFR |
13.13NM AFR |
. | . | . | . |
| 2000 | 2.50NM LF |
5.00NM NF |
7.50NM AFR |
10.00NM AFR |
12.50NM AFR |
15.00NM AFR |
. | Note 1 | . | . |
| 2250 | 2.81NM LF |
5.62NM NF |
8.44NM AFR |
11.25NM AFR |
14.06NM AFR |
. | . | . | . | . |
| 2500 | 3.13NM LF |
6.25NM NF |
9.38NM AFR |
12.50NM AFR |
. | . | . | . | . | . |
| Note 1: Larger Area Dampers Utilise Multiple Damper Actuators | ||||||||||
| Reference Table - Spring Return Damper Actuators | |||||
Damper Size |
|||||
TF24 TF24-SR |
24V 24V |
On/Off 0-10V Modulating |
|||
LF24 LF24-SR |
24V 24V |
On/Off 0-10V Modulating |
|||
NF24 NF24-SR |
24V 24V |
On/Off 0-10V Modulating |
|||
AFR24 AFR24-SR |
24V 24V |
On/Off 0-10V Modulating |
|||
| Non-Spring Return Damper Actuators Width (mm) and Height (mm) |
||||||||||
| 250 | 0.31NM CMU |
0.63NM CMU |
0.94NM CMU |
1.25NM CMU |
1.56NM CMU |
1.88NM CMU |
2.19NM LMU |
2.50NM LMU |
2.81NM LMU |
3.13NM LMU |
| 500 | 0.63NM CMU |
1.25NM CMU |
1.88NM CMU |
2.50NM LMU |
3.13NM LMU |
3.75NM LMU |
4.38NM LMU |
5.00NM LMU |
5.63NM NMU |
6.25NM NMU |
| 750 | 0.94NM CMU |
1.88NM CMU |
2.81NM LMU |
3.75NM LMU |
4.69NM LMU |
5.63NM NMU |
6.56NM NMU |
7.50NM NMU |
8.44NM NMU |
9.38NM NMU |
| 1000 | 1.25NM CMU |
2.50NM LMU |
3.75NM LMU |
5.00NM LMU |
6.25NM NMU |
7.50NM NMU |
8.75NM NMU |
10.00NM NMU |
11.25NM SMU |
12.50NM SMU |
| 1250 | 1.56NM CMU |
3.13NM LMU |
4.69NM LMU |
6.25NM NMU |
7.81NM NMU |
9.38NM NMU |
10.94NM SMU |
12.50NM SMU |
14.06NM SMU |
15.63NM SMU |
| 1500 | 1.88NM CMU |
3.75NM LMU |
5.63NM NMU |
7.50NM NMU |
9.38NM NMU |
11.25NM SMU |
13.13NM SMU |
15.00NM SMU |
16.88NM SMU |
18.75NM SMU |
| 1750 | 2.19NM LMU |
4.38NM LMU |
6.56NM NMU |
8.75NM NMU |
10.94NM SMU |
13.13NM SMU |
15.31NM SMU |
17.50NM SMU |
19.69NM SMU |
21.88NM GMU |
| 2000 | 2.50NM LMU |
5.00NM LMU |
7.50NM NMU |
10.00NM NMU |
12.50NM SMU |
15.00NM SMU |
17.50NM SMU |
20.00NM SMU |
22.50NM GMU |
25.00NM GMU |
| 2250 | 2.81NM LMU |
5.63NM NMU |
8.44NM NMU |
11.25NM SMU |
14.06NM SMU |
16.88NM SMU |
19.69NM SMU |
22.50NM GMU |
25.31NM GMU |
28.13NM GMU |
| 2500 | 3.13NM LMU |
6.25NM NMU |
9.38NM NMU |
12.50NM SMU |
15.63NM SMU |
18.75NM SMU |
21.88NM GMU |
25.00NM GMU |
28.13NM GMU |
31.25NM GMU |
| Reference Table - Non-Spring Return Damper Actuators | |||||
Damper Size |
|||||
CMU24 CMU24-SR-R |
24V 24V |
On/Off 0-10V Modulating |
|||
LMU24 LMU24-SR |
24V 24V |
On/Off 0-10V Modulating |
|||
NMU24 NMU24-SR |
24V 24V |
On/Off 0-10V Modulating |
|||
SMU24 SMU24-SR |
24V 24V |
On/Off 0-10V Modulating |
|||
GMU24 GMU24-SR |
24V 24V |
On/Off 0-10V Modulating |
|||
| Equation For Determining Damper Torque (NM) | |||||
Damper Torque = Damper Width x Damper Height x Force Generated By The Airflow NB: In These Tables, The Force Generated By The Pressure And Velocity Of A Normal Air-conditioning System Is Approximately 5.00NM/m2. In A Higher Pressure System, This Value Could Be As High As 20.00NM/m2. |
|||||